Denver air conditioner compressors typically fail due to a single of two circumstances: time and hours of operation (wear out), or abuse. There are some failures that can come about elsewhere in the method that will cause a compressor failure, but these are less widespread unless of course the method has been considerably abused.
This improper service can incorporate overcharging, undercharging, putting in the wrong starter capacitor as a substitute, getting rid of (fairly than repairing/changing) the thermal limiter, insufficient oil, mixing incompatible oil kinds, or wrong oil, putting in the compressor on a system that had a main burnout without having taking correct measures to eliminate the acid from the program, putting in the incorrect compressor (also tiny) for the technique, or putting in a new compressor on a program that had some other failure that was in no way diagnosed.
The compressor can fail in only a handful of different methods. It can fail open, fail shorted, experience a bearing failure, or a piston failure (throw a rod), or encounter a valve failure. That is fairly considerably the entire list.
This is unserviceable and the symptom is that the compressor does not run, although it might hum. Pop the electrical cover for the compressor off, and take away the wires and the thermal limiter. Employing an ohmmeter, measure the impedance from one particular terminal to one more across all three terminals of the compressor. Also measure the impedance to the situation of the compressor for all three terminals.
You should go through lower impedance values for all terminal to terminal connections (a few hundred ohms or much less) and you must have a high impedance (a number of kilo-ohms or larger) for all terminals to the circumstance (which is floor). In this scenario, the broken wire has moved and is contacting the case. This problem - which is rather uncommon but not not possible - could trigger a breaker to trip and could outcome in a misdiagnosis of failed brief. When a Denver air conditioner compressor fails brief, what occurs is that insulation on the wires has worn off or burned off or broken within the compressor. This permits a wire on a motor winding to touch a thing it need to not touch - most generally alone a turn or two further along on the motor winding. Lousy bearings can result in a failed quick. Possibly the rotor wobbles enough to get in touch with the stator, resulting in insulation damage that shorts the rotor either to floor or to the stator, or stop bearing put on can permit the stator to shift down over time until it starts to rub from the stator ends or the housing.
Usually when 1 of these shorts happen, it is not promptly a tough brief - which means that at first the speak to is intermittent and arrives and goes. Although the short is in spot, the current by means of the shorted winding shoots up and a great deal of heat is created. About time (quite possibly a couple of weeks, usually much less) the shuddering and the sparking and the heat and the acid result in insulation to fail rapidly on the winding. Eventually, the winding loses ample insulation that the within of the compressor is actually burning. This will only go on for a couple of minutes but in that time the compressor destroys itself and fills the program with acid. It might at that time melt a wire loose and brief to the housing (which can trip your residence main breaker) or it might not. If the first cause of the failure was bad bearings creating the rotor to rub, then generally when the factor finally dies it will be shorted to the housing.
If it shorts to the housing, it will blow fuses and/or breakers and your ohmmeter will display a very lower impedance from a single or much more windings to ground. If it does not brief to the housing, then it will just quit. You still set up the sort of failure utilizing an ohmmeter.
You can't directly diagnose a failed short with an ohmmeter unless of course it shorts to the housing - a shorted winding won't display up with an ohmmeter even though it would with an inductance meter (but who has 1 of individuals?) Rather, you have to infer the failed quick. You do this by establishing the the ohmmeter provides typical readings, the starter capacitor is great, power is arriving at the compressor, AND an acid test of the freon shows acid current.
With a failed short, just give up. Modify every little thing, like the lines if doable. It is not well worth repairing; it is full of acid and as a result is all junk. More, a failed quick could have been in the beginning induced by some other failure in the method that caused a compressor overload; by changing the full method you also will get rid of that likely other problem.
Less normally, a compressor will have a bearing failure, piston failure or a valve failure. Additional seldom, they can signal another failure in the method this kind of as a reversing valve dilemma or an expansion valve dilemma that winds up letting liquid freon get into the suction facet of the compressor.
If a bearing fails, typically you will know because the compressor will sound like a motor with a undesirable bearing, or it will lock up and refuse to run. In the worst scenario, the rotor will wobble, the windings will rub on the stator, and you will wind up with a failed brief.
If the compressor locks up mechanically and fails to run, you will know since it will buzz really loudly for a handful of seconds and may well shudder (just like any stalled motor) right up until the thermal limiter cuts it off. When you do your electrical checks, you will locate no evidence of failed open or failed brief. The acid test will show no acid. In this scenario, you might attempt a difficult-begin kit but if the compressor has failed mechanically the difficult-begin kit won't get the compressor to begin. Right after replacing the compressor, you should carefully evaluate the efficiency of the total system to determine regardless of whether the compressor dilemma was induced by some thing else.
If it is operating happily, then the moment you have established that there is in fact loads of freon in the process, but practically nothing is shifting, then you have no selection but to alter the compressor. Once more, a method with a compressor that has had a valve failure is a very good candidate for a new compressor.
Now, if the compressor is mechanically locked up it could be since of a few of points. If the compressor is on a heat pump, make certain the reversing valve is not stuck fifty percent way. Also make sure the expansion valve is functioning; if it is blocked it can lock the compressor. Also make positive the filter is not clogged. I once noticed a technique that had a locked compressor due to liquid lock. Believe in me; that does not perform.
Need to diagnosis present a clogged filter, then this need to be taken as optimistic evidence of some failure in the program OTHER than a compressor failure. Generally, it will be metal fragments out of the compressor that clogs the filter. This can only come about if one thing is causing the compressor to wear really swiftly, especially in the pistons, the rings, the bores, and the bearings. Either the compressor has vastly insufficient lubrication OR (and much more generally) liquid freon is finding into the compressor on the suction line. Occasionally, this technique will start off suitable up if you whack the compressor with a rubber mallet whilst it is buzzing. This kit stores power and, when the compressor is advised to start off, dumps additional current into the compressor for a second or so. This overloads the compressor, but provides some excess torque for a short time and is frequently sufficient to make that compressor run yet again. And this, in a nutshell, is what can happen to an air conditioner compressor and what you can do about it.
Subscribe to:
Post Comments (Atom)
South Palm BeachVery useful blog. Thanks for this wonderful post.
ReplyDeleteI would really like to thank you for this great job, because it’s very helpful for individual like me. Thanks... Gulf Stream HVAC Contractor FL
ReplyDeleteGreat information in here, thanks for sharing! Boca Raton AC Repair Boca Air Conditioning
ReplyDeleteThanks for sharing these kind of information. Hope this will useful to so many people who all are reading this blog. Keep posting like these, thanks once again Ac Repair Service in Bengaluru | Ac Repair Service in Bhopal | Ac Repair Service in Gurgaon
ReplyDelete